Product Name:Heating Wire
Configuration
Applications
The heater wire are mainly used in domestic appliances, cold industry and some machines where either freeze protection or temperature maintenance is required.
Technical data
|
RXV |
RXG |
Diameter |
From Ø2mmto Ø3mm |
From Ø2mmto Ø3.5mm |
Winding support |
From Ø0.5mmto Ø1.5mmfiberglass core |
|
Heating element |
Nickel-Chromium or Copper-Nickel alloy wire |
|
Electrical insulation |
105℃PVC |
Silicon rubber |
Tolerances |
±5% on resistance +0.2/-0.1mmon diameter |
|
Output |
Up to 15W/m |
Up to 40W/m |
Voltage |
Max. 600V |
|
Max. cable surface temperature |
105℃ |
200℃ |
Min. cable surface temperature |
-30℃ |
-70℃ |
Heating cords can be supplied with a braid for mechanical protection and earthing.
·Fiberglass
·Tinned copper
·Stainless steel wire
·Aluminum Magnesium alloy wire